Title of article
Boiling heat transfer characteristics of R-113 in a vertical small diameter tube under natural circulation condition
Author/Authors
Chowdhury Feroz Md، نويسنده , , Fumito Kaminaga، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
7
From page
4823
To page
4829
Abstract
Boiling heat transfer characteristics of freon R-113 are experimentally investigated in a vertical small diameter tube, D=1.45 mm and L=100 mm at a wide pressure range of 19–269 kPa under natural circulation condition. Except the entrance region of the test section, the flow regime is annular in view of the measured vapor flux. The pool boiling correlations of Stephan and Abdelsalam and McNelly equally well predict the experimental data within an error of ±20%. No enhancement of heat transfer coefficient is obtained although D/B is less than 1.5, which differs from the finding of Klimenko.
Keywords
Two-phase flow , Heat transfer enhancement , Low pressure , Natural circulation , Small diameter tube
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2002
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1071310
Link To Document