• Title of article

    Boiling heat transfer characteristics of R-113 in a vertical small diameter tube under natural circulation condition

  • Author/Authors

    Chowdhury Feroz Md، نويسنده , , Fumito Kaminaga، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    7
  • From page
    4823
  • To page
    4829
  • Abstract
    Boiling heat transfer characteristics of freon R-113 are experimentally investigated in a vertical small diameter tube, D=1.45 mm and L=100 mm at a wide pressure range of 19–269 kPa under natural circulation condition. Except the entrance region of the test section, the flow regime is annular in view of the measured vapor flux. The pool boiling correlations of Stephan and Abdelsalam and McNelly equally well predict the experimental data within an error of ±20%. No enhancement of heat transfer coefficient is obtained although D/B is less than 1.5, which differs from the finding of Klimenko.
  • Keywords
    Two-phase flow , Heat transfer enhancement , Low pressure , Natural circulation , Small diameter tube
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Serial Year
    2002
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Record number