Author/Authors :
N.R.، Harris, نويسنده , , M.، Hill, نويسنده , , N.M.، White, نويسنده , , S.P.، Beeby, نويسنده ,
Abstract :
Direct acoustic measurements have been performed on a range of thick-film PZT ultrasonic transducer constructions, and these are compared with their electrical impedance and calculated input powers. They show good efficiency when driving into water, and a significant improvement over a similarly constructed bulk PZT transducer.