• Title of article

    Thermal analysis on metal-foam filled heat exchangers. Part II: Tube heat exchangers

  • Author/Authors

    C.Y. Zhao، نويسنده , , W. Lu، نويسنده , , S.A. Tassou، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    9
  • From page
    2762
  • To page
    2770
  • Abstract
    The forced convection heat transfer characteristics in high porosity open-cell metal-foam filled tube heat exchangers are analysed in this paper. The Brinkman-extended Darcy momentum model and two-equation heat transfer model for porous media are employed for the analysis of the heat transfer performance. The morphological effects of metal foams on overall heat transfer are examined. The optimal foam-area ratio for a metal-foam filled counter-flow tube-in-tube heat exchanger is predicted. The study shows that the thermal performance of a metal-foam heat exchanger can be superior to that of conventional finned tube heat exchangers.
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Serial Year
    2006
  • Journal title
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
  • Record number

    1074153