Title of article
Pressure drop studies on two-phase flow in a uniformly heated vertical tube at pressures up to the critical point
Author/Authors
B.R. Vijayarangan، نويسنده , , S. Jayanti and G. F. Hewitt، نويسنده , , A.R. Balakrishnan، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
13
From page
1879
To page
1891
Abstract
Measurements of two-phase flow pressure drop have been made during a phase-change heat transfer process with refrigerant (R-134a) as a working fluid for a wide range of pressures right up to the critical pressure. The experiments were conducted in a uniformly heated vertical tube of 12.7 mm internal diameter and 3 m length over a heat flux range of 35–80 kW/m2, mass flux range of 1200–2000 kg/m2 s, exit quality range of 0.19–0.81 and for reduced pressures ranging from 0.24 to 1 with a fixed inlet subcooling of 3 °C. The measurements were compared with the predictions from the homogeneous flow model, a separated flow model using correlations drawn from the literature for void fraction and frictional pressure drop, and finally, using a flow pattern-based predictive method accounting specifically for bubbly, slug and annular flow regimes. It was found that the best results were obtained with the flow pattern-based approach with a mean deviation of ±20% over the entire pressure range.