Title of article
Numerical study on transverse asymmetry in the temperature profile of a regenerator in a pulse tube cooler
Author/Authors
Stig Kildegaard Andersen، نويسنده , , Marc Dietrich، نويسنده , , Henrik Carlsen، نويسنده , , Günter Thummes، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
10
From page
2795
To page
2804
Abstract
Transverse asymmetry in the temperature profile of the regenerator in a Stirling-type pulse tube cooler as observed in experiments was analysed in a numerical study. The asymmetry was reproduced using a one-dimensional model of the cooler where the regenerator was modelled using two identical parallel regenerator channels. The asymmetry was caused by a circulating flow that was superimposed on the oscillating flow. The primary mechanism driving the circulating flow was due to the wave form of the pressure difference between the ends of the regenerator and the dependence of the instantaneous mass flow rate on the pressure difference and temperature.
Keywords
Temperature profile , Transverse asymmetry , Streaming , Circulating flow , Regenerator , Pulse tube cooler