Effects of water and iso-propyl alcohol relative humidities on single wafer cleaning system performance
Author/Authors
J. Koo، نويسنده , , T. Kim، نويسنده , , C. Jung، نويسنده , , J. Lee، نويسنده , , T. Kim، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
11
From page
4275
To page
4285
Abstract
As the pattern size scales down and the wafer size increases, the particle defects should be controlled more strictly in the modern microelectronics fabrication. Single wafer cleaning processes are introduced in the industry due to higher particle removal efficiency and lower particle reattachment possibility. In this study, the origins of watermark defects in single wafer cleaning system were identified, and the ways to avoid the problems were suggested through a model based numerical simulation. The watermark defects observed in the single wafer cleaning systems were found to originate from the failure of controlling water and iso-propyl alcohol (IPA) relative humidities in the surrounding gas. Increasing the IPA relative humidity in the surrounding gas during the drying phase could improve watermark defects and increase product yields.
Keywords
Evaporation , Single wafer cleaning , Relative humidity , Watermark defect