Title of article
An experimental investigation of the effect of longitudinal fin orientation on heat transfer in membrane water wall tubes in a circulating fluidized bed
Author/Authors
Anusorn Chinsuwan، نويسنده , , Animesh Dutta، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
9
From page
1552
To page
1560
Abstract
Experiments were conducted in a cold model circulating fluidized bed having riser cross-sectional area of 100 mm × 100 mm, height of 4.8 m, bed temperature of 75 °C and superficial velocity of 8 m s−1. Local sand having average diameter of 231 μm was used as bed material. The experiments were conducted for three tube configurations: membrane tube, membrane tube with a longitudinal fin at the tube crest and membrane tube with two longitudinal fins at 45° on both sides of the tube crest. The results show that membrane tubes with one and two longitudinal fins have higher heat transfer than membrane tubes and the heat is mainly transferred in the combination portion of tube and membrane fins. In addition, the membrane tube has the highest heat transfer coefficient.
Keywords
Membrane water wall tube , Finned tube , Heat transfer coefficient , Circulating fluidized bed
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2009
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1075922
Link To Document