Title of article
Film cooling at hypersonic Mach numbers using forward facing array of micro-jets
Author/Authors
R. Sriram، نويسنده , , G. Jagadeesh Chandran، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
11
From page
3654
To page
3664
Abstract
Experimental investigations are carried out in the IISc hypersonic shock tunnel on film cooling effectiveness of a single jet (diameter 2 mm and 0.9 mm), and an array forward facing of micro-jets (diameter 300 μm each) of same effective area (corresponding to the respective single jet). The single jet and the corresponding micro-jets are injected from the stagnation zone of a blunt cone model (58° apex angle and nose radius of 35 mm). Nitrogen and Helium are injected as coolant gases. Experiments are performed at freestream Mach number 5.9, at 0° angle of attack, with a stagnation enthalpy of 1.84 MJ/kg, with and without injections. The ratios of the jet stagnation pressure to the freestream pitot pressure used in the present study are 1.2 and 1.45. Up to 50% reduction in surface heat transfer rate was observed with the array of micro-jets, compared to that of the respective single jet with nitrogen as the coolant, while the corresponding reduction was up to 37% for helium injection, with the schlieren flow visualizations showing no major change in the shock standoff distance, and thus no major changes in other aerodynamic aspects such as drag.
Keywords
Hypersonic flow , Film cooling , Forward facing jet/micro jets
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2009
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
1076145
Link To Document