Title of article :
Experimental study on the operating characteristics of a capillary pumped loop with a flat evaporator
Author/Authors :
Wukchul Joung، نويسنده , , Hyungjin Hwang، نويسنده , , Jinho Lee، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Abstract :
Recent advances in electronics technology have led to growing demand for highly efficient heat transfer devices with operating temperature controllability. Although capillary pumped loops are excellent candidates for this requirement and have been successful in various applications, their typical cylindrical evaporator shape has been a major drawback for applications to flat heat sources. Moreover, operating characteristics and the corresponding physical understanding of the capillary pumped loops are still uncertain, and lack of data for their operation makes their application unreliable. Thus, in this work, a capillary pumped loop with a flat evaporator was devised, and its operating characteristics were investigated.
Keywords :
Capillary pumped loop , Reservoir temperature control , Flat evaporator , Operating temperature control
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER