Evaporation from a meniscus of heptane liquid in a V-groove geometry is experimentally investigated. A thin layer of titanium coated on the backside of the fused quartz groove is electrically heated to provide a constant heat flux. The temperature profile in the evaporating thin film region of the extended meniscus is measured using high-resolution infrared thermography and the temperature suppression in this region is obtained as a function of liquid feeding rate. The meniscus shape is captured using a goniometer. A temperature suppression of ∼0.2 K in the 150 μm region surrounding the contact line on each side indicates the efficacy of evaporation in the extended meniscus. At a given axial location, the fraction of total meniscus heat transfer which takes place in a 50 μm sub-region measured from the contact line is estimated by an approximate heat balance analysis to be ∼45% for the range of liquid feeding rates explored.