Title of article :
Lifetime-based phosphor thermometry of an optical engine using a high-speed CMOS camera
Author/Authors :
Satoshi Someya، نويسنده , , Mitsunori Uchida، نويسنده , , Kaoru Tominaga، نويسنده , , Hayato Terunuma، نويسنده , , YanRong Li، نويسنده , , Koji Okamoto، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
6
From page :
3927
To page :
3932
Abstract :
The surface temperature inside an optical engine was measured both with and without heating the intake gas. The temperature distribution was measured by lifetime-based phosphor thermometry using 10 time-sequential images during a single decay recorded by a non-intensified high-speed complementary metal oxide semiconductor camera and by accounting for the pixel-to-pixel variation in the nonlinearity of the sensor. Consequently, the system was simple and compact. One goal of this research is to use a single camera to measure the temperature field because it is easy to use such a system in practical experiments. The shot-to-shot standard deviation of the decay constant for uniform temperature conditions was 0.17–0.33% at 80–160 °C and it varied ±0.15% with position, indicating that the pixel nonlinearity is highly nonuniform. The present measurement method had a measurement error of −2.25 to 1.15 °C and it exhibited a similar level of shot-to-shot fluctuations (±0.42–2.34 °C). This technique was used to measure the temperature in an optical engine and it gave reasonable temperature maps.
Keywords :
Phosphor , Temperature , Lifetime , Visualization , CMOS
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year :
2011
Journal title :
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number :
1077412
Link To Document :
بازگشت