Title of article
Heat transfer through a double-glazed unit with an internal louvered blind: Determination of the thermal transmittance using a biquadratic equation
Author/Authors
M. Karmele Urbikain، نويسنده , , José M. Sala، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
10
From page
1226
To page
1235
Abstract
The aim of this research is to quantify the influence of a louvered blind in a double-glazed unit during night-time conditions. First, an analytical study of free convection was conducted to obtain a set of correlations for the Nusselt numbers of the cavity. Second, a parametric study was performed to calculate the total heat transfer (convective and long-wave radiative) during night-time conditions. The analysis accounted for aspect ratio, blind thermal conductivity, surface emissivity and slat angle. Using these data, a biquadratic equation was developed to calculate the U-factor of a double-glazed unit with an internal louvered blind in terms of the U-factor of the unit without the blind, slat surface emissivity and slat angle.
Keywords
Heat-transfer coefficient , Double-glazed unit , Window , U-factor , Thermal transmittance , Blind