Title of article
On the accuracy of the diffusion coefficient measurements using different initial shear cell configurations at low and moderate Rayleigh numbers
Author/Authors
Oriol Batiste and Xavier Ruiz ، نويسنده , , Jordi Pallares، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2012
Pages
13
From page
6966
To page
6978
Abstract
Three different shear cell arrangements are considered here in order to discuss and compare the accuracy of their measurements at low and moderate Rayleigh number, that is to say, in reduced gravity environments. To do so, specific numerical procedures have been designed in order to quantitatively estimate the corresponding associated errors as a function of time and at the end of the diffusive process. The present work clearly shows that the interdiffusion-couple configuration is, from the point of view of accuracy, the worst one.
Keywords
microgravity , High temperature binary mixtures , Interdiffusion coefficients , Numerical modeling