Title of article
OPTIMUM DIMENSIONS OF WAFFLE SLAB FOR MEDIUM SIZE FLOORS
Author/Authors
Chander، S. نويسنده , , Prasad، J. نويسنده , , Ahuja، A.K. نويسنده ,
Issue Information
دوفصلنامه با شماره پیاپی سال 2005
Pages
-182
From page
183
To page
0
Abstract
Waffle slab has had its genesis in a rather thick solid-slab floor from which the bottom layer concrete in tension is partially replaced by their ribs along orthogonal directions. The ribs are reinforced with steel to resist flexural tensile stresses. The dimensions and spacing of ribs are decided in a manner so as to achieve better load distribution without requiring the shear reinforcement. The present paper elaborates the results obtained from the analytical study carried out on waffle slab medium size floor system with a view to achieve the optimum dimensions of rib spacing, its depth and width. The waffle slab has been considered as monolithically connected to band beams. Feasibility of structural design of members has been ensured under the provision of IS: 456-2000.
Keywords
waffle slab , medium size floor , R.C.C. slab , optimization
Journal title
Asian Journal of Civil Engineering (Building and Housing)
Serial Year
2005
Journal title
Asian Journal of Civil Engineering (Building and Housing)
Record number
108139
Link To Document