Title of article
On performance measures of reverse osmosis plants Original Research Article
Author/Authors
M. Hajeeh، نويسنده , , Zeid A. AlOthman، نويسنده , , E. El-Sayed، نويسنده , , S. Al-Fuliaj، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
6
From page
335
To page
340
Abstract
This analysis presented in this paper assesses the difference in the performance measures due to the inclusion of an energy recovery system into a small reverse osmosis (RO) in terms of plant availability. The failure behavior of an RO plant including an energy recovery Pelton wheel turbine is analyzed along with its operational time. The plant is divided into main subsystems and the availability/unavailability of each subsystem is derived. the overall availability of the RO plant with and without the energy recovery turbine are derived from the performance of its subsystems and were compared. Assessment of the operational time of the plant was considered to be more appropriate than other performance measures since the plant was designed for continuous operation. The plant subjective assessment of failure probabilities of subsystems was made wherever detailed data were not available.
Keywords
performance measures , Energy recovery system , Operational time , Availability
Journal title
Desalination
Serial Year
2002
Journal title
Desalination
Record number
1107660
Link To Document