Title of article :
Scale-up of microfiltration systems: fouling phenomena and Vmax analysis Original Research Article
Author/Authors :
Andrew L. Zydney، نويسنده , , Chia-Chi Ho، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
7
From page :
75
To page :
81
Abstract :
Proper sizing and scale-up of normal flow filtration devices requires an understanding of the effects of membrane fouling on system capacity. The Vmax test is often used to accelerate testing and reduce the required process volume, but the underlying assumption that fouling occurs by uniform constriction of cylindrical membrane pores is rarely met in practice. We have examined the validity of the Vmax model and have compared the results with predictions of a new model that accounts for fouling due to both pore blockage and cake formation. The Vmax analysis significantly over-estimates the system capacity for proteins like bovine serum albumin that foul primarily by pore blockage, but it under-estimates the capacity for lysozyme which fouls primarily by cake formation. In contrast, the pore blockage—cake filtration model provides a much better description of membrane fouling, leading to more accurate sizing and scale-up of normal flow filtration devices.
Keywords :
Microfiltration , Fouling , Normal flow filtration , Scale up , Filter sizing
Journal title :
Desalination
Serial Year :
2002
Journal title :
Desalination
Record number :
1107752
Link To Document :
بازگشت