Title of article
Use of membrane technology for potable water production Original Research Article
Author/Authors
M. Arora، نويسنده , , R.C. Maheshwari، نويسنده , , Dharmendra Kumar, S.K. Jain، نويسنده , , A. Gupta، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
8
From page
105
To page
112
Abstract
Excess fluoride in drinking water is harmful for human health, so it is necessary to be removed. In this study thepotential of a reverse osmosis (RO)membrane for defluoridation of underground water samples at different solute concentrations was studied. Because of the variation in feed water composition, its chemical properties, pH and operating conditions, effect of these parameters on the membrane separation process was studied. The results showed that pH, feed water composition, flow rate and pressure affect the membrane efficiency, and thus proper control of these factors is essential for successful operation, Optimum membrane properties and proper rejection were determined percentage for the RO system to minimize the overall cost of water treatment. The samples were collected from three villages in the Gurgaon district and treated at optimized conditions. The results indicate that RO membranes can be successfully used for the treatment of underground water to the desired purity level, as they remove up to 95% of fluoride present in water and also take care of other ions present in water.
Keywords
Defluoridation Reverse osmosis Membrane Underground water
Journal title
Desalination
Serial Year
2004
Journal title
Desalination
Record number
1108847
Link To Document