Title of article :
Exergy analysis of a combined RO, NF, andEDR desalination plant Original Research Article
Author/Authors :
Nafiz Kahraman، نويسنده , , Yunus A. Cengel، نويسنده , , Byard Wood، نويسنده , , Yunus Cerci، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
16
From page :
217
To page :
232
Abstract :
A brackish water desalination plant in California that incorporates RO, NF, and EDR units was analyzedthermodynamically using actual plant operation data. Exergy flow rates were evaluated throughout the plant, and the exergy flow diagrams were prepared. The rates of exergy destruction and their percentage are indicated on the diagram so that the locations of highest exergy destruction can easily be identified. The analysis shows that most exergy destruction occurs in the pump/motor and the separation units. The fraction of exergy destruction in the pump/motor units is 39.7% for the RO unit, 23.6% for the NF unit, and 54.1 % for the EDR unit. Therefore, using high-efficiency pumps and motors equipped with VFD drives can reduce the cost of desalination significantly. The plant was determined to have a Second Law efficiency of 8.0% for the RO unit, 9.7% for the NF unit, and 6.3% for the EDR unit, which are very low. This indicates that there are major opportunities in the plant to improve thermodynamic: performance by reducing exergy destruction and thus the amount of electrical energy supplied, making the operation of the plant more cost effective.
Keywords :
Desalination , Electrodialysis , Nanofiltration , Exergy analysis , Reverse osmosis
Journal title :
Desalination
Serial Year :
2005
Journal title :
Desalination
Record number :
1108880
Link To Document :
بازگشت