Title of article
Separation of ethylene glycol solution by vacuum membrane distillation (VMD) Original Research Article
Author/Authors
T. Mohammadi، نويسنده , , M. Akbarabadi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
7
From page
35
To page
41
Abstract
The feasibility of VMD for concentration of ethylene glycol (EG) from a used coolant liquid is presented. VMD experiments were performed with water-EG mixtures using a flat-sheet polypropylene membrane at various temperatures and recirculation rates. Results show that the membrane almost completely rejects EG and the desired concentration was achieved. This is due to the vapor pressure of EG being negligible compared to that of water. Increasing temperature and recirculation rate increased flux with no effect on EG rejection. Increasing of feed flow rate higher than 0.67 had no strong effect on permeate flux.
Keywords
membrane
Journal title
Desalination
Serial Year
2005
Journal title
Desalination
Record number
1109257
Link To Document