• Title of article

    Water usage in variable volume diafiltration: comparison with ultrafiltration and constant volume diafiltration Original Research Article

  • Author/Authors

    Greg Foley، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    4
  • From page
    160
  • To page
    163
  • Abstract
    Variable volume diafiltration (VVD), also known as volume-decreasing diafiltration, is a process in which fresh water is added continuously to the retentate in a batch ultrafiltration process at a rate that is less than the permeate flowrate, thus providing for simultaneous ultrafiltration (UF) and diafiltration. This process has been analysed recently and it is claimed that VVD uses less water than constant volume diafiltration (CVD) . In this paper, we examine both VVD and UF–CVD and compare the water usage in each process. For a solution containing two solutes, A and B, with rejection coefficients σA = 1 and σB = 0, we show that VVD uses more water than CVD when CVD is performed at the final volume of a UF–CVD process. VVD uses less water than CVD only if the latter is performed at the initial volume of a UF–CVD process. When CVD is performed at the intermediate macrosolute concentration that minimises the process time, namely Cg/e where Cg is the gel concentration and e is the base of the natural logarithm, it will generally use less water than VVD.
  • Keywords
    Water usage , Ultrafiltration , Constant volume diafiltration , Variable volume diafiltration , Optimisation
  • Journal title
    Desalination
  • Serial Year
    2006
  • Journal title
    Desalination
  • Record number

    1109933