Title of article :
Effect of fouling reduction by ozone backwashing in a microfiltration system with advanced new membrane material Original Research Article
Author/Authors :
Jong-Oh Kim، نويسنده , , Jong-Tae Jung، نويسنده , , Ick-Tae Yeom، نويسنده , , Gyung-Hae Aoh، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
8
From page :
361
To page :
368
Abstract :
The effect of ozone back washing for membrane fouling reduction was experimentally investigated in a submerged metal membrane microfiltration system. A cleaning by intermittent ozone gas backwashing was effective in recovering the permeation flux. Intermittent ozone backwashing was highly effective than the air or permeates backwashing for flux recovery. Regarding the operational parameters, the increase of ozone gas flow rate was more effective than the increase of injection time under the conditions of same ozone dose. However, the backwashing cycle was longer, the effect of flux recovery by ozone backwashing decreased. Therefore, it is favorable to operate membrane cleaning before the foulant was consolidated on membrane surface.
Keywords :
Ozone backwashing , Gas flow rate , Injection time , Submerged microfiltration , Fouling
Journal title :
Desalination
Serial Year :
2007
Journal title :
Desalination
Record number :
1110589
Link To Document :
بازگشت