Title of article :
Implications of enhancing critical flux of particulates by AC fields in RO desalination and reclamation Original Research Article
Author/Authors :
Y.P. Zhang، نويسنده , , T.H. Chong، نويسنده , , A.G Fane، نويسنده , , A. Law، نويسنده , , H.G.L. Coster، نويسنده , , H. Winters، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
9
From page :
371
To page :
379
Abstract :
This paper discusses fouling in reverse osmosis in terms of the critical flux of foulants and the fouling mechanisms based on hydraulic resistance and loss of driving force due to cake-enhanced osmotic pressure (CEOP). In many cases CEOP is the dominant effect and this is exacerbated by the use of constant flux processing. The implications of increasing critical flux are described and the potential benefit of using AC field gradients to do this is illustrated for a model foulant.
Keywords :
Fouling , Reverse osmosis , Critical flux , AC field