• Title of article

    Elimination of biological fouling in seawater reverse osmosis desalination plants Original Research Article

  • Author/Authors

    Nobuya Fujiwara، نويسنده , , Hideto Matsuyama ، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    11
  • From page
    295
  • To page
    305
  • Abstract
    The main trouble in the RO method of seawater desalination is biological fouling (bio-fouling) from microorganism growth. In this work, the growth rate of microorganisms in the Red Sea and sterilization by chlorine injection were measured and quantified. Furthermore, actual demonstration of RO pilot tests using cellulose tri-acetate (CTA) RO membranes with chlorine resistance was performed in RO plants where bio-fouling actually occurred. By carrying out direct chlorine sterilization of the RO membrane with an intermittent chlorine injection method, bio-fouling was eliminated. The combination of the CTA membrane and chlorine injection successfully prevented increases of differential pressure and stabilized product water quantity and quality.
  • Keywords
    Reverse osmosis membrane , Biological fouling , Pilot plant test , Intermittent chlorine injection
  • Journal title
    Desalination
  • Serial Year
    2008
  • Journal title
    Desalination
  • Record number

    1111659