• Title of article

    Removal of boron from geothermal water by RO system-II-effect of pH Original Research Article

  • Author/Authors

    Emre Yavuz، نويسنده , , ?zgür Arar، نويسنده , , Mithat Yuksel، نويسنده , , Umran Yüksel، نويسنده , , Nalan Kabay، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    5
  • From page
    135
  • To page
    139
  • Abstract
    In this study, the effect of pH as a function of number of membranes employed on boron removal from geothermal water containing boron was investigated by using a mini-pilot scale brackish water reverse osmosis (BWRO) system. When the pH of geothermal water was increased to 10.5, boron rejection obtained was 94.5–95% for both single and double membrane configurations at 12 bar of operating pressure. At pH 10.5, the boron concentration of the product water was around 0.5 mg/L which is suitable according to irrigation standards. On the other hand, it was observed that the average permeate flux and water recovery values decreased when the pH of feed water was increased from 8.0 to 10.5 for both single and double membrane configurations.
  • Keywords
    Boron , Desalination , Geothermal water , Reverse osmosis
  • Journal title
    Desalination
  • Serial Year
    2013
  • Journal title
    Desalination
  • Record number