Title of article
Demineralization of geothermal water reverse osmosis (RO) permeate by electrodeionization (EDI) with layered bed configuration Original Research Article
Author/Authors
?zgür Arar، نويسنده , , Umran Yüksel، نويسنده , , Nalan Kabay، نويسنده , , Mithat Yuksel، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
7
From page
48
To page
54
Abstract
In this study, demineralization of reverse osmosis (RO) permeate of geothermal water by electrodeionization (EDI) method was investigated. The layered bed configuration of EDI system consists of Purolite A 500 anion exchange and Purolite CT 175 cation exchange resins in the central compartment. Selemion AME anion exchange and Selemion CME cation exchange membranes were used to separate the central compartment from the electrode compartments. The effects of applied voltage, feed flow rate and the concentration of Na2SO4 solution in the electrode compartments on product water quality were investigated. According to the results obtained, the average conductivity of RO permeate decreased from 15.0 μS/cm to 2.9 μS/cm in the product water when the applied voltage was increased. It was possible to obtain a product water with an average conductivity of 1.0 μS/cm by the increase in the feed flow rate.
Keywords
Electrodeionization , Geothermal water , Ion exchange membrane , Ion exchange resin , Layered bed configuration , RO permeate
Journal title
Desalination
Serial Year
2013
Journal title
Desalination
Record number
1115739