Title of article :
Characteristics of permeate-side spacers of spiral wound membrane modules
Author/Authors :
C.P. Koutsou، نويسنده , , A.J. Karabelas، نويسنده , , T.B. Goudoulas، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
6
From page :
131
To page :
136
Abstract :
Reliable estimates of the effective lateral permeability (k) of permeate-side spacers of spiral wound membrane (SWM) elements are required in order to design them and simulate module and plant performance. Such permeability data are not available at present. A straightforward approach is recommended for determining k of spacers under modest pressure, which involves pressure drop measurements in a spacer-filled channel coupled with separate accurate data on the effect of normal pressure on spacer thickness. Application of this approach to typical spacers from commercial SWM modules shows that k is at the level of 2 to 3.5 × 10− 10 m2, for measured thickness 0.20 to 0.25 mm. The tested spacers exhibit modest compaction under pressure, with a tendency to approach asymptotically a minimum thickness at a pressure smaller than that prevailing in tightly wound membrane envelopes of commercial modules. Recommendations are also outlined regarding R & D directions on the selection of appropriate permeate spacers in the context of overall optimization of SWM module design and desalination process performance.
Keywords :
SWM design and performance optimization , Water desalination , Permeate-side spacer , SWM module , Effective permeability
Journal title :
Desalination
Serial Year :
2013
Journal title :
Desalination
Record number :
1115838