Title of article
Vacuum membrane distillation for purifying waters containing arsenic Original Research Article
Author/Authors
Alessandra Criscuoli، نويسنده , , Patrizia Bafaro، نويسنده , , Enrico Drioli، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2013
Pages
5
From page
17
To page
21
Abstract
In this work, the potentialities of Vacuum Membrane Distillation (VMD) for treating water containing arsenic, both in the trivalent and pentavalent form, were analyzed, with the aim of producing a purified permeate working at low feed temperatures (20 °C–40 °C). Experimental tests were carried out on a commercial flat membrane module varying the arsenic concentration, the arsenic form (trivalent or pentavalent), the membrane, the operating temperatures and flow-rates. Long-term tests were also performed. The membrane area was of 180 cm2 and the vacuum pressure was fixed at 10 mbar. In all tests, no arsenic was detected in the permeate and the highest flux ranged between 3 and 12.5 kg/hm2 at 20 °C and 40 °C, respectively.
Keywords
Trivalent and pentavalent arsenic , Vacuum membrane distillation , Arsenic rejection , Arsenic contaminated water
Journal title
Desalination
Serial Year
2013
Journal title
Desalination
Record number
1115841
Link To Document