Title of article
Reuse of anaerobically and aerobically pre-treated textile wastewater by UF and NF membranes Original Research Article
Author/Authors
Eyup Debik، نويسنده , , Gul Kaykioglu، نويسنده , , Asli Coban، نويسنده , , Ismail Koyuncu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
7
From page
174
To page
180
Abstract
The aim of this study is to compare different pre-treatment techniques before the use of UF and NF membranes for textile industry effluents. Three different applications are discussed. First, raw textile wastewater effluent was applied to membranes (direct filtration of raw wastewater). After that, aerobically (full scale aerobic treatment plant (SBR) effluent that is present in the factory) and anaerobically (laboratory scale anaerobic treatment plant effluent) pre-treated effluents were compared with UF and NF membranes. UF and/or NF experiments were carried out at the laboratory scale and investigated at different operating pressures. The study showed that aerobic pre-treatment gave better performance prior to membrane filtration, and NF treatment with UF pre-treatment was the most suitable option for the effluents, as determined by different standards of permeate quality and quantity for different purposes in factories.
Keywords
Reuse , Textile wastewater , Ultrafiltration , Nanofiltration , Aerobic treatment , Anaerobic treatment
Journal title
Desalination
Serial Year
2010
Journal title
Desalination
Record number
1116586
Link To Document