• Title of article

    BRADOS – Dose determination in the Russian Segment of the International Space Station Original Research Article

  • Author/Authors

    M. Hajek، نويسنده , , T. Berger، نويسنده , , M. Fugger، نويسنده , , M. Fuerstner، نويسنده , , N. Vana، نويسنده , , Y. Akatov، نويسنده , , V. Shurshakov، نويسنده , , V. Arkhangelsky، نويسنده ,

  • Issue Information
    دوهفته نامه با شماره پیاپی سال 2006
  • Pages
    4
  • From page
    1664
  • To page
    1667
  • Abstract
    In the frame of the joint experiment BRADOS-1, absorbed dose and average linear energy transfer were assessed by means of 7LiF:Mg,Ti (TLD-700) thermoluminescence detectors for different panels onboard the Russian Segment of the International Space Station in the timeframe between February and October 2001 (248 days). A technique is presented to correct the measured absorbed dose values for thermoluminescent efficiency in the radiation climate onboard the spacecraft. Average linear energy transfer is determined from the high-temperature thermoluminescence emission in the TLD-700 glowcurve and used as a parameter in the thermoluminescent-efficiency correction. Depending on the shielding distribution, the efficiency–corrected absorbed dose varies between 168(2) μGy/d in panel No. 318 (core block ceiling) and 249(4) μGy/d in panel No. 443 (starboard-side commander cabin). The experimental data are compared with model calculations using detailed shielding distributions and orbit parameters as input.
  • Keywords
    BRADOS , Thermoluminescent efficiency , Space dosimetry , HTR , Thermoluminescence
  • Journal title
    Advances in Space Research
  • Serial Year
    2006
  • Journal title
    Advances in Space Research
  • Record number