Title of article :
Simulation of microelectrode impedance changes due to cell growth
Author/Authors :
Huang، Xiaoqiu نويسنده , , Nguyen، Duc نويسنده , , D.W.، Greve, نويسنده , , M.M.، Domach, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
-575
From page :
576
To page :
0
Abstract :
Observation of impedance changes caused by cell growth on microelectrodes provides information about cell coverage and other important quantities, such as the cell-electrode gap. In this paper, we use finite-element simulations to calculate the impedance changes caused by cell growth on electrodes comparable in size to the cell. Parameters describing the impedance of the electrode without cells are derived from measurement. The results show that the impedance magnitude is expected to increase by at least 100% for partial cell coverage. We also report the frequency dependence of the magnitude and phase of the impedance and compare the simulation results with a lumped-element model. The simulation results are important for the design and modeling of arrays of cell-sized electrodes and also for the interpretation of experiments.
Keywords :
liquid crystalline polymer , XRD , Ethylene-Propylene Copolymer , TGA , DSC , DMTA , Microstructure
Journal title :
IEEE Sensors Journal
Serial Year :
2004
Journal title :
IEEE Sensors Journal
Record number :
114860
Link To Document :
بازگشت