Title of article
Ultrasound measurements to monitor the specific gravity of food batters Original Research Article
Author/Authors
Paul Fox، نويسنده , , Penny Probert Smith، نويسنده , , Sarab Sahi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
8
From page
317
To page
324
Abstract
This paper describes the design and application of a low cost ultrasound system to monitor the specific gravity of batter as it is mixed. The quantity of air is believed to be the main factor in determining the quality of the finished product and specific gravity measurement is common for assessing the quality and progress of the mixing process. A probe is designed to allow measurements in reflection and the relationship of ultrasound gain to specific gravity determined theoretically and justified experimentally. Operation was conducted in pulsed mode using a nominally 2.25 MHz, 15 mm diameter transducer. The work may have application to measurements on industrial sludges in which similar material properties are observed.
Keywords
Specific gravity , Ultrasound , Aerated foams , Bubbles
Journal title
Journal of Food Engineering
Serial Year
2004
Journal title
Journal of Food Engineering
Record number
1165962
Link To Document