Title of article
Heat transfer coefficients measurement in industrial freezing equipment by using heat flux sensors Original Research Article
Author/Authors
Alvaro Amarante، نويسنده , , Jean-Louis Lanoisellé، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
10
From page
377
To page
386
Abstract
Heat transfer coefficients, either for convection or conduction mechanisms were determined by using heat flux sensors coupled to temperature measurement devices. Three distinct pieces of equipment were assessed with respect to their heat transfer capabilities. The dynamic variability of heat transfer coefficients was determined along the processing length of a conduction–convection SuperContact® tunnel and a fluidized bed freezer. The main sources of heat transfer inefficiency were uneven air speed profiles for convection and high thermal contact resistance for conduction mechanisms. Fluctuation of coolant temperature was determined to be the limiting factor in a plate freezer. Simulations either with Tylose® gel (SuperContact® tunnel) or with mashed carrot (plate freezer) were carried out to predict improvement in heat transfer coefficients.
Keywords
Heat flux sensor , Heat transfer coefficient , Freezing , Heat flux
Journal title
Journal of Food Engineering
Serial Year
2005
Journal title
Journal of Food Engineering
Record number
1166044
Link To Document