• Title of article

    Local surface heat transfer coefficients on a model beef side Original Research Article

  • Author/Authors

    Jim Willix، نويسنده , , Mark B. Harris، نويسنده , , James K. Carson، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    7
  • From page
    561
  • To page
    567
  • Abstract
    Measurements of heat transfer coefficients were performed at 11 different positions on the surface of a fibreglass model of a side of beef for a range of free stream velocities and turbulence intensities, using customised heat transfer sensors and commercial heat flux sensors. There was wide variation between the results at the different measurement positions; for low velocities or high turbulence intensities, the difference between the maximum and minimum value was as high as 140% of the mean. For free stream velocities below 1 m s−1, the heat transfer coefficients measured at the tenderloin position were very low, which suggested that there was very poor air movement around the sensor due to its position in a semi-enclosure within the intestinal cavity. The heat transfer coefficients at most of the sensor positions followed the usual power law dependence on air velocity.
  • Keywords
    Heat transfer coefficient , Beef side , Carcass
  • Journal title
    Journal of Food Engineering
  • Serial Year
    2006
  • Journal title
    Journal of Food Engineering
  • Record number