Title of article
Design and development of apparatus to provide repeatable surface temperature–time treatments on inoculated food samples Original Research Article
Author/Authors
Alan M. Foster، نويسنده , , Laurence P. Ketteringham، نويسنده , , Mark J. Swain، نويسنده , , Alain Kondjoyan، نويسنده , , Michel Havet، نويسنده , , Olivier Rouaud، نويسنده , , Judith A. Evans، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
12
From page
7
To page
18
Abstract
The majority of data relating heat treatments to thermal death kinetics has previously been obtained by carrying out in vitro tests on small samples of microorganisms in growth medium or food slurries. However, strong evidence exists that suggests microbial death on heat-treated food surfaces cannot be predicted accurately from such systems. An apparatus was therefore designed to enable microbial death on food surfaces to be quantified.
The apparatus uses hot air to provide a ‘dry’ heat treatment to raise the surface of a food sample to a given temperature, up to 100 °C, hold and then cool it. The surface temperature was measured using an infra-red (IR) thermometer and the air heater was controlled to give a specified surface temperature history. Steam was also used to provide a ‘wet’, but less controlled heating cycle.
Keywords
Food poisoning , Surface decontamination , Microbial models , Heating and cooling equipment , Surface temperature measurements
Journal title
Journal of Food Engineering
Serial Year
2006
Journal title
Journal of Food Engineering
Record number
1166611
Link To Document