Title of article :
Silo flow-pattern diagnosis using the tracer method Original Research Article
Author/Authors :
Nathalie Job، نويسنده , , Albert Dardenne، نويسنده , , Jean-Paul Pirard، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
The storage silo of a sugar refinery was designed by its manufacturer for a plug-flow pattern of sugar ingots in order to ensure effective drying of the sugar introduced at the top of the silo. Because of the excessive moisture content of the extracted ingots, the quality of flow within the silo was called into question. The silo flow-pattern was thus studied by introducing sugar lumps as a tracer at the top of the silo filled with ingots. The tracer weight percentage was measured at the outlet. Results show that the silo flow-pattern is not of the plug-flow type in its whole volume: after formation of a crater, only the central volume flows, while the outer residual volume remains motionless. The tracer test also enabled the detection of preferential flow patterns. The tracer method was found to be quite useful as a diagnosis method for such a device in normal functioning.
Keywords :
Storage , Tracer test , Solid flowing , Silo
Journal title :
Journal of Food Engineering
Journal title :
Journal of Food Engineering