Title of article :
Residence time distribution in holding tubes using generalized convection model and numerical convolution for non-ideal tracer detection Original Research Article
Author/Authors :
Carola G.C.C. Gutierrez، نويسنده , , Eduardo F.T.S. Dias، نويسنده , , Jorge A.W. Gut، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Abstract :
A procedure is proposed for the determination of the residence time distribution (RTD) of curved tubes taking into account the non-ideal detection of the tracer. The procedure was applied to two holding tubes used for milk pasteurization in laboratory scale. Experimental data was obtained using an ionic tracer. The signal distortion caused by the detection system was considerable because of the short residence time. Four RTD models, namely axial dispersion, extended tanks in series, generalized convection and PFR + CSTR association, were adjusted after convolution with the E-curve of the detection system. The generalized convection model provided the best fit because it could better represent the tail on the tracer concentration curve that is caused by the laminar velocity profile and the recirculation regions. Adjusted model parameters were well correlated with the flow rate.
Keywords :
Residence time distribution , Laminar flow model , Pasteurization , Aseptic processing
Journal title :
Journal of Food Engineering
Journal title :
Journal of Food Engineering