• Title of article

    Field measurement of airborne sound insulation between rooms with non-diffuse sound fields at low frequencies

  • Author/Authors

    C. Hopkins، نويسنده , , P. Turner، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    44
  • From page
    1339
  • To page
    1382
  • Abstract
    Procedures for the field measurement of airborne sound insulation between rooms with diffuse fields are described in International Standard ISO 140-4. However, many dwellings contain rooms with volumes less than 50 m3, where low frequency measurements are less reliable; hence there is a need for a measurement procedure to improve the reliability of field measurements in rooms with non-diffuse fields. Procedures are proposed for sound pressure level and reverberation time measurements for the 50, 63 and 80 Hz third octave bands. The sound pressure level measurement combines corner microphone positions with positions in the central region of each room. This provides a good estimate of the room average sound pressure level with significantly improved repeatability.
  • Keywords
    ISO 140 , Sound insulation , Low frequency , Reverberation time , Repeatability , Sound pressure level
  • Journal title
    Applied Acoustics
  • Serial Year
    2005
  • Journal title
    Applied Acoustics
  • Record number

    1170802