• Title of article

    Indoor Noise Reduction Index with an open window (Part II)

  • Author/Authors

    C. Buratti، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    19
  • From page
    383
  • To page
    401
  • Abstract
    An index to evaluate indoor noise level reduction with an open window Noise Reduction Index (NRI) was proposed [Buratti C. Indoor Noise Reduction Index with open window. Appl Acoust 2002;63(4):431–51]. The reduction was due to the installation of a false ceiling in the room, thus reducing the contribution of the reverberant field. Experimental data related to two different kinds of false ceiling were compared to the results obtained by an original calculation model. Good agreement was found between experiments with two different materials and predictions. The present paper examines six different kinds of false ceiling and arrives at a new validation of the model. Calculations of NRI show good agreement with experimental data: a maximum difference of −1.2 dB(A) was found with a mean difference of 0.5 dB(A) for a wide range of absorption coefficient values. Hence the model represents a reliable instrument for indoor NRI prediction, if the acoustic absorption characteristics of materials are known.
  • Keywords
    Open window , Noise Reduction Index (NRI) , Spectrum and Leq(A) measurements , Buildings acoustic insulation , model validation , Road
  • Journal title
    Applied Acoustics
  • Serial Year
    2006
  • Journal title
    Applied Acoustics
  • Record number