Title of article
Research on performance indices of vibration isolation system
Author/Authors
H.L. Sun، نويسنده , , X.F. Guo and H.B. Chen، نويسنده , , K. Zhang، نويسنده , , P.Q. Zhang، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
7
From page
789
To page
795
Abstract
Power flow transmissibility is proposed as a performance index to evaluate the performance of isolation system. It is defined as the ratio of the power flow input into the equipment and the power flow transmitted into the receiver. Based on a simple vibration isolation system, its relationship with other performance indices is given by theoretical and numerical analysis. The results show that power flow transmissibility can reflect the response characteristics of the whole isolation system effectively. In addition, power flow transmissibility can be estimated easily according to vibration acceleration level difference and does not involve the measurement of power flow. Furthermore, the influences of several parameters such as the damping, loss factor and stiffness of isolator on power flow transmissibility are analyzed.
Keywords
Power flow , Performance index , Vibration , Isolation