Title of article :
Cryogenic contamination of an ultra-low loss mirror for cryogenic laser interferometric gravitational wave detector Original Research Article
Author/Authors :
Shinji Miyoki، نويسنده , , Takashi Uchiyama، نويسنده , , Takayuki Tomaru، نويسنده , , Daisuke Tatsumi، نويسنده , , Hideki Ishizuka، نويسنده , , Masatake Ohashi، نويسنده , , Kazuaki Kuroda، نويسنده , , Akitoshi Ueda، نويسنده , , Toshikazu Suzuki، نويسنده , , Nobuaki Sato، نويسنده , , Tomiyoshi Haruyama، نويسنده , , Akira Yamamoto، نويسنده , , Takakazu Shintomi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
6
From page :
61
To page :
66
Abstract :
The reflectance of ultra-low loss dielectric multilayer coating mirrors cooled at 10 K was monitored as the finesse of a Fabry–Perot cavity consisting of them for one month. Their reflectances remained approximately constant within ±5 ppm. The contaminated reflectance due to the cryogenic molecule absorption was investigated to be recovered without any serious damage on their coating surface. This result suggests utilization of the cryogenic mirror is likely for the interferometric gravitational wave detector.
Keywords :
Interferometric gravitational wave detector , Cryogenic contamination , Finesse , Reflectance , Ultra-low loss dielectric multilayer coating mirror
Journal title :
Cryogenics
Serial Year :
2000
Journal title :
Cryogenics
Record number :
1172000
Link To Document :
بازگشت