Dielectric strength, swelling and weight loss of the ITER Toroidal Field Model Coil insulation after low temperature reactor irradiation Original Research Article
Author/Authors :
K. Humer، نويسنده , , H.W Weber، نويسنده , , R. Hastik، نويسنده , , Thomas H. Hauser، نويسنده , , H. Gerstenberg، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
7
From page :
295
To page :
301
Abstract :
The insulation system for the Toroidal Field Model Coil of ITER is a fiber reinforced plastic (FRP) laminate, which consists of a combined Kapton/R-glass–fiber reinforcement tape, vacuum-impregnated with an epoxy DGEBA system. Pure disk shaped laminates, FRP/stainless-steel sandwiches, and conductor insulation prototypes were irradiated at 5 K in a fission reactor up to a fast neutron fluence of 1022 m−2 (E>0.1 MeV) to investigate the radiation induced degradation of the dielectric strength of the insulation system. After warm-up to room temperature, swelling, weight loss, and the breakdown strength were measured at 77 K. The sandwich swells by 4% at a fluence of 5×1021 m−2 and by 9% at 1×1022 m−2. The weight loss of the FRP is 2% at 1×1022 m−2. The dielectric strength remained unchanged over the whole dose range.
Keywords :
Insulating material , Swelling , Electrical properties , Weight loss , Irradiation