Title of article :
Experimental study on pulse tube refrigeration with helium and nitrogen mixtures Original Research Article
Author/Authors :
Z.H Gan، نويسنده , , G.B. Chen، نويسنده , , Günter Thummes، نويسنده , , C Heiden، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
7
From page :
333
To page :
339
Abstract :
An experimental investigation on two-component multi-phase helium and nitrogen mixtures in a single-stage pulse tube refrigerator was carried out. The experimental results show that both coefficient of performance (COP) and cooling power can be improved to some extent at above 70 K when the nitrogen fraction in the mixture is less than 25%. An approximate stable temperature platform at the triple point 63.15 K of nitrogen, which is independent of nitrogen’s fraction, is obtained when the cooling power is below 7 W.
Keywords :
Two-phase flow , Gas mixtures , Pulse tube
Journal title :
Cryogenics
Serial Year :
2000
Journal title :
Cryogenics
Record number :
1172034
Link To Document :
بازگشت