Title of article :
The effect of operating parameters in the Stirling cryocooler Original Research Article
Author/Authors :
S.J. Park، نويسنده , , Y.J. Hong، نويسنده , , H.B. Kim، نويسنده , , D.Y. Koh، نويسنده , , J.H. Kim، نويسنده , , B.K. Yu، نويسنده , , K.B. Lee، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
7
From page :
419
To page :
425
Abstract :
This paper presents design, manufacturing process and test results in the optimum operating condition for the free piston free displacer (FPFD) type Stirling cryocooler designed and manufactured by Korea Institute of Machinery and Materials. FPFD Stirling cryocooler is currently under development for cooling infrared detector. The compressor in the Stirling cryocooler uses opposed linear motors to drive opposed pistons. The performance of FPFD Stirling cryocooler is evaluated as a function of charging pressure and operating frequency. In general, as the charging pressure is increased, optimum-operating frequency of the compressor is increased but resonant frequency of the displacer is almost constant. The prototype has achieved no load temperature of 49 K and cooling power of 0.5 W at 72 K.
Keywords :
Cooling capacity , Operating frequency , Charging pressure
Journal title :
Cryogenics
Serial Year :
2002
Journal title :
Cryogenics
Record number :
1172270
Link To Document :
بازگشت