    Experimental measurements of the flow resistance and inductance of inertance tubes at high acoustic amplitudes Original Research Article

  • Author/Authors

    Y.L. Ju، نويسنده , , G.Q. He، نويسنده , , Y.K. Hou، نويسنده , , J.T. Liang، نويسنده , , Y. Zhou، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    7
  • From page
    1
  • To page
    7
  • Abstract
    We measured the flow resistance and flow inductance of inertance tubes at high acoustic amplitudes for four different inner diameters of 0.6, 1.0, 1.5 and 2.0 mm at various tube length ranging from 100 to 1500 mm, at frequencies of 30, 40, 50, 60 and 70 Hz. The experiments were carried out under system mean pressure of 20 bar at room temperature. The experimental data were compared with the explicit solution to the linear momentum equation for small acoustic amplitudes and were fitted with the modification coefficients in terms of the operating frequency and Reynolds numbers characterized by the amplitude of gas velocities.