• Title of article

    “Dry” dilution refrigerator with pulse-tube precooling Original Research Article

  • Author/Authors

    Kurt Uhlig، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    5
  • From page
    53
  • To page
    57
  • Abstract
    We present construction details and performance measurements of a “dry” dilution refrigerator which is precooled by a pulse-tube refrigerator; no cryo-liquids are required to operate this cryostat. The dilution refrigerator is equipped with a double mixing chamber and reaches a lowest temperature of 4.3 mK. The 3He throughput of the refrigerator was between 100 and 300 μmol/s. The total heat leak into the mixing chamber was determined to be 75 nW. For thermometry we had a 3He melting-curve thermometer at our disposal. Ease of operation and reliability are the characteristics of this type of cryostat.
  • Keywords
    Dilution refrigerator , Vibrations , Pulse-tube refrigerator
  • Journal title
    Cryogenics
  • Serial Year
    2004
  • Journal title
    Cryogenics
  • Record number