Title of article :
Optimum operating conditions for an adsorption cryocooler: a case of activated carbon + nitrogen system Original Research Article
Author/Authors :
Radhika Rani Rao، نويسنده , , Madhu Prasad، نويسنده , , Kandadai Srinivasan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
5
From page :
193
To page :
197
Abstract :
Adsorption cryocoolers are among the possible options for obtaining cryogenic temperatures, in particular for small cooling capacity applications such as cooling of infra red detectors. They need to be optimized for liquid yield. The performance of thermal compressors therein pivots around the adsorption characteristics of the adsorbent + adsorbate combination and how effectively one could pack requisite amounts of adsorbent into a given volume of the compressor housing. In addition, the overall performance of the cooler is a function of limits of operating temperatures and pressures across the compressor. This paper proposes a performance indicator—the product of liquid yield and the uptake efficiency of the compressor—and evaluates its values for various possible operating conditions for one specimen of activated carbon. It is shown that there is a limited domain of operation and that there is a condition of best performance within that domain.
Journal title :
Cryogenics
Serial Year :
2005
Journal title :
Cryogenics
Record number :
1172530
Link To Document :
بازگشت