• Title of article

    Thermal performance of multilayer insulation around a horizontal cylinder Original Research Article

  • Author/Authors

    T. Ohmori، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    8
  • From page
    725
  • To page
    732
  • Abstract
    Thermal performance of multiplayer insulation (MLI) is affected by contact pressure between adjacent layers. In order to evaluate the thermal performance of the MLI fabricated in the horizontal cryostats of superconducting magnets, it is important to investigate the contact pressure in the MLI. In case of a horizontal cryostat, the MLI is wound around horizontal cylindrical surface and is compressed at the upper part of the cylinder due to the MLI self-weight. At first, a single thin film wound around the horizontal cylinder was analyzed to evaluate the contact pressure acting on the cylinder. The analysis has been extended to the multiply wound film around horizontal cylinder, in order to investigate the distribution of contact pressure between adjacent layers. By using experimental data obtained with a flat panel calorimeter, the results of this analysis have been applied to evaluate the thermal performance of MLI around a horizontal cylinder. And the non-dimensional contact pressure parameter P∗ has been introduced as a useful parameter to evaluate and compare the thermal performance among different kinds of MLI.
  • Keywords
    Multilayer insulation , Cryostats (F) , Superconducting magnets (F) , Transmission lines (F) , Heat Transfer (C)
  • Journal title
    Cryogenics
  • Serial Year
    2005
  • Journal title
    Cryogenics
  • Record number