Abstract :
In contrast to the ideal case of unlimited size recuperator, any real Linde–Hampson machine of finite size recuperator can be optimized to reach the extreme rates of performance. The group of cryocoolers sharing the same size recuperator is optimized in a closed form by determining the corresponding flow rate which maximizes its rate of cold production. For a similar group of liquefiers an optimal flow rate is derived to maximize the rate of production of liquid cryogen. The group of cryocoolers sharing a constant and given flow rate is optimized by shortening the recuperator for reaching a maximum compactness measured by the cooling power per unit size of the recuperator. The optimum conditions are developed for nitrogen and argon. The relevance of this analysis is discussed in the context of practice of fast cooldown Joule–Thomson cryocooling.
Keywords :
Joule–Thomson coolers (E) , Cycle optimization (E) , Fast cooldown cryocoolers , Linde–Hampson liquefier