Title of article
Performance modeling of optical refrigerators Original Research Article
Author/Authors
Gary Mills، نويسنده , , Allan Mord، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
7
From page
176
To page
182
Abstract
Optical refrigeration using anti-Stokes fluorescence in solids has several advantages over more conventional techniques including low mass, low volume, low cost and no vibration. It also has the potential of allowing miniature cryocoolers on the scale of a few cubic centimeters. It has been the topic of analysis and experimental work by several organizations. In 2003, we demonstrated the first optical refrigerator.
We have developed a comprehensive system-level performance model of optical refrigerators. Our current version models the refrigeration cycle based on the fluorescent material emission and absorption data at ambient and reduced temperature for the Ytterbium–ZBLAN glass (Yb:ZBLAN) cooling material. It also includes the heat transfer into the refrigerator cooling assembly due to radiation and conduction.
In this paper, we report on modeling results which reveal the interplay between size, power input, and cooling load. This interplay results in practical size limitations using Yb:ZBLAN.
Keywords
Cryogenics , Optical refrigeration , Modeling , Laser
Journal title
Cryogenics
Serial Year
2006
Journal title
Cryogenics
Record number
1172624
Link To Document