Abstract :
In this paper, we introduce a new kind of two-stage pulse tube refrigerators. The chosen entire coaxial configuration combines the advantages of the coaxial design with the two-stage pulse tube concept. Lead coated screens build the inhomogeneous regenerator matrix of the second stage. Without any rare earth compounds the refrigerator reaches a no load temperature of 6.6 K at the second stage cold tip. The active type of phase shifting is generated by a rotary valve combined with two needle valves at the hot end of each pulse tube (compressor Leybold RW 6000, 6 kW input power). This paper focuses on the design parameters and first performance measurements.